Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling

Product Details
Customization: Available
After-sales Service: Free Spare Parts
Warranty: 12 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Experienced Team
The supplier has 6 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (13)
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
  • Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Our Advantages
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
customized
Type
Air-Cooled
Cooling Water
Industrial Water
System Type
Closed System
Fans Species
Double-speed fan
Noise Level
Low
Application Fields
Immersion Cooling
Certification
ISO
Condition
New
Tube Material
Stainless Steel, Aluminum, Hot DIP Carbon Steel
Defrost
Hot Gas Defrost, Electrical Defrost, Water Defrost
Fin Space
5-20mm
Fin Material
Aluminum, Stainless Steel, Hot DIP Carbon Steel
Mounting
Floor Standing
Transport Package
Wooden Package
Specification
According to the product
Trademark
VRCOOLER
Origin
China
Production Capacity
2000PCS/Months

Packaging & Delivery

Package Size
400.00cm * 120.00cm * 1425.00cm
Package Gross Weight
300.000kg

Product Description

Product Description

Dry coolers are mainly for machine cooling, process cooling, oil cooling, free cooling and cold room cooling.

   For bitcoin serve farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers.

Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
 
Detailed Photos

 

TECHNICAL SPECIFICATION
TUBES
Aluminium, copper, stainless steel, cu-ni, titanium
12 mm, 1/2", 5/8", 20mm, 25mm
FINS
Aluminum, copper, stainless steel, titanium
CASING MATERIAL
Thick. 1 - 3 mm
Galvanized steel, Aluminium, Stainless steel, Copper,Brass
 
Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
Name: Tube
Standard tubes are 5/8", 1/2" ,5/8", 20, 1" OD, 
304, 316 stainless steel, copper, titanium, hot dip galvanized steel or aluminum.
Tubes are arranged inline in the direction of airflow for maximum heat transfer with minimum air side pressure drop. 

 
Name: Fin
Standard fin material is aluminum, copper, stainless steel, titanium.  
Fins are die-formed into a corrugated (waffle) configuration to encourage turbulent airflow and improve heat transfer efficiency. Fins do have varied types of space.
Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling

 
Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
Name: Cabinet
Standard cabinet/casing material is corrosion resistant galvanized steel.
We also supply aluminum, stainless steel cabinet and casing
 
Product Parameters

Vrcooler Provide two solution for our customer.
One Immersion Cooling Solution is Dry Cooler direct cooling.
Another Immersion cooling solution is Dry coolers and plate heat exchangers combined with indirect cooling. This is currently the most popular and economical cooling methods.
We designed standard dry cooler model for immersion cooling system. From 40KW to 240KW. Customized immersion cooling solution also available.
40KW Dry Cooler for Immersion Cooling System:
Suitable for the single immersion enclosure.

40KW Dry Cooler Direct Cooling
40KW Dry Cooler with Plate Heat Exchanger Indirect Cooling
Capactiy:
40KW
Capactiy:
40KW
Fluid Temperature(Inlet/Outlet)(ºC)
60/40
WATER Temperature(Inlet/Outlet)(ºC)
40/60
Air Temperature(Inlet/Outlet)(ºC)
35/46.1
Liquid
Temperature(Inlet/Outlet)(ºC)
65/45
Power Standard
220V/1Ph/50Hz
No. of plates
73
Dimensions
1687x700x952mm
No. of effective plates
71
Material:
Copper Tube Aluminum Fin GI Steel powder coating Casing
Plate material
ALLOY 316
 
 
Thickness
0.4mm
 
 
Number of passes
4
Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling

120KW Dry Cooler for Immersion Cooling System:

Suitable for the Immersion Rack System.
120KW Dry Cooler Direct Cooling
120KW Dry Cooler with Plate Heat Exchanger Indirect Cooling
Capactiy:
120KW
Capactiy:
120KW
Fluid Temperature(Inlet/Outlet)(ºC)
60/40
WATER Temperature(Inlet/Outlet)(ºC)
40/60
Air Temperature(Inlet/Outlet)(ºC)
35/46.1
Liquid Temperature(Inlet/Outlet)(ºC)
65/45
Power Standard
460V/1Ph/60Hz
No. of plates
121
Dimensions
3410x1115x700mm
No. of effective plates
119
Material:
Copper Tube Aluminum Fin GI Steel powder coating Casing
Number of passes
4
 
 
Extension capacity
4
 
 
Plate material
ALLOY 316
 
 
Thickness(mm)
0.4

240KW Dry Cooler for Immersion Cooling System:

Suitable for the multiple Immersion Racks.
240KW Dry Cooler Direct Cooling
240KW Dry Cooler with Plate Heat Exchanger Indirect Cooling
Capactiy:
240KW
Capactiy:
240KW
Fluid Temperature(Inlet/Outlet)(ºC)
60/40
WATER Temperature(Inlet/Outlet)(ºC)
40/60
Air Temperature(Inlet/Outlet)(ºC)
35/45.85
Liquid Temperature(Inlet/Outlet)(ºC)
65/45
Power Standard
460V/1Ph/60Hz
 
 
Dimensions
4165X2100X1710mm
 
 
Material:
Copper Tube Aluminum Fin GI Steel powder coating Casing
 
 
Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling
 
Our Advantages

1) We can help buyers design specific products or produce products according to buyers' design.
2) We has exported to many countries,such as Israel, USA, German, Canada etc.
3)Rapid response to your needs: We will reply within 24 hours after receiving you letter. If you have urgent thing, welcome to call us.
4)The Most Efficient Service, Best Quality and Excellent Reputation.

Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling

 
Company Profile

MORE THAN 15 YEARS OF SUCCESS
Changzhou Vrcoolertech Refrigeration Co.,Ltd specializes in researching, manufacturing and exporting Heat Exchangers, Evaporators, Condensers, air cooler and other heat transfer equipments for the varied industries since 2004.

OUR MISSION
We are committed to quality products and services to meet our customer's expectations and the needs of industrials. We are dedicated to our mission and goal and we believe in long term business relationship with our customers which is based on integrity, responsiveness and quality.

Water Glycol Mixture 250kw Dry Cooler for Data Center Cooling

 
FAQ

Q1. Are you manufacturer or Trade Company?
We are manufacture factory and we can accept OEM order.

Q2. What's the order process?
1) Inquiry---provide us all clear requirements.
2) Quotation---official quotation list with all clear specifications.
3) PI--Confirm all the order technical data and price
4) Payment terms--- T/T deposit in advance
5) Production---mass production
6) Shipping--- by sea. Detailed picture of package will be provided.
7) After-sales Service--Any questions, we will try best to assist to solve for you.

Q3. How to get a prompt quotation?
When you send the inquiry to us, pls kindly send it with below technical information.
A. Function: Cooling only or cooling and heating?
B. Capacity: _____KW or ___Ton
C. Refrigerant: R407C, R410a or R134a
D. Voltages and Frequency : ______V/PH/HZ
E.Application:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier