Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System

Product Details
Customization: Available
After-sales Service: Free Spare Parts, Video Technical Support, Online
Warranty: 1 Year
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Experienced Team
The supplier has 6 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (13)
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
  • Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Find Similar Products
  • Overview
  • Product Description
  • Product Application
  • Our Advantages
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Part Number
Type
Air Cooler
Air Tube Material
Aluminum
Corrosion Durability
General
Operating Voltage
220/440VAC, 380/400 VAC, Optional
Noise Level
Ordinary
Application Fields
Data Center, Power Plant, Sewage Treatment Plant
Mounting
Floor Standing
Certification
RoHS, ISO
Condition
New
Applicable Industries
Hotels, Garment Shops, Building Material Shops
Core Components
Tube Fin Heat Exchanger
Refrigerant
Ammonia
Dimensions
Customized
Application
Heating System
Material
Copper, Ss, Aluminum
Weight (Kg)
220kg
Tube Material
Copper, Stainless Steel
Fin Material
Copper, Aluminum, Stainless Steel
Transport Package
Wooden Case
Specification
220KG
Trademark
CST
Origin
Jiangsu
HS Code
8415909000
Production Capacity
500 Unit/Units Per Month

Product Description

Product Description

Jenbacher engine remote radiators are a special type of radiator that is usually used in situations where the engine needs to be kept away from the generator. In this case, the radiator needs to be placed separately outside the generator room in order to keep the engine within the temperature range required for proper operation.

Jenbacher engine remote radiators are usually used g dry cooler type radiators. A radiator is a type of radiator in which coolant is piped to the inside of the radiator, where it exchanges heat with the outside air and circulates the coolant back to the engine.

Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Jenbacher engine remote radiators offer the following advantages:

Reduced noise: moving the radiator away from the generator room reduces the noise generated by the generator running and improves the quietness of the surrounding environment.

Improved cooling efficiency: a radiator located away from the generator room makes fuller use of the surrounding air, improving cooling efficiency and thus keeping the engine within the temperature range required for proper operation.

Easy maintenance: moving the radiator away from the generator room also makes the radiator easier to maintain, as it can be replaced or cleaned without affecting the operation of the generator.

Vrcooler can supply radiators for Jenbacher gas engines and can supply radiators in the following models but not limited to:
JMS 316 GS-N.L Gas Engine Rediator
Jenbacher JMS 320 GS-N.L Gas Engine Rediator
GE Jenbacher JGC 320 GS-L.L Gas Engine Rediator
GE Jenbacher JGC 320 GS-S.L Gas Engine Rediator
GE Jenbacher JMS 420 GS-B.L Gas Engine Rediator
GE Jenbacher JMS 312 GS-B.L Gas Engine Rediator
GE Jenbacher JMS 208 GS-B.L Gas Engine Rediator
Jenbacher JGS 420 B25 Gas Engine Rediator
GE Jenbacher JGS 620 GS-S.L Gas Engine Rediator
GE Jenbacher JMC 420 B28 Gas Engine Rediator
Jenbacher JGS616 and Jenbacher JGS624 Gas Engine Rediator
GE's Jenbacher Type 6 engines J620 Gas Engine Rediator
Jenbacher JMC 208 GS LL Gas Engine Rediator
Product Application


1. Dry Air Cooler for Immersion Cooling Tank

Provide a reliable, low energy and safe air cooled heat exchanger for the cooling of immersion bath.
Fluid to be cooled is dielectric coolant manufactured by Engineered Fluids.
 
High quality and reliable Vrcooler fluid cooler with redundant fans to keep the bath cool in a safe and consistent manner
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System

2. Dry Cooler in Milk Cooling System, Replace a Water Chiller
Milk cooling is an important part of the production process of the ranch. The plate heat exchanger is the place where the milk is cooled.
Through efficient heat exchange, there is no need to worry about mixing the cooling medium into the milk.
VRcooler provides solutions for milk cooling, as shown in the picture below:
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
3. Dry Cooling System in Diesel Generator Set Cooling, Replace Cooling Tower
In a power plant, the largest use of water is in the cooling system, as a lot of heat must be removed to condense the steam used to drive the turbine generator.
Historically, cooling was provided by water sources - rivers and lakes, but now, water conservation is a priority for power generation companies. More and more power plants are using.
Cooling method: The water in the Dry Cooling System uses a heat exchanger to cool the circulating water or oil inside the generator.Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Food industry: Dry coolers are used in the food industry to cool food products and ingredients during production and to maintain temperatures in storage facilities. They are commonly used in dairy processing, meat processing, and in the production of baked goods.

Oil and gas industry: Dry coolers are used in the oil and gas industry to cool various process fluids, such as crude oil, condensate, and natural gas. They are used in refining and petrochemical processing, as well as in upstream oil and gas operations.

Agriculture: Dry coolers are used in agriculture for crop cooling and storage. They are used to cool and maintain the quality of fruits, vegetables, and other perishable agricultural products.
 
Solar energy: Dry coolers are used in concentrated solar power (CSP) plants to cool the thermal fluid used in the heat transfer process.

Mining industry: Dry coolers are used in the mining industry to cool process fluids, such as water and glycol, used in the mining process. They are also used to cool air in underground mining operations.

Medical and pharmaceutical industry: Dry coolers are used in the medical and pharmaceutical industry to cool equipment and products, such as medical lasers and vaccines, which require stable and precise temperatures.
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
 
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Plastics industry: Dry coolers are used in the plastics industry to cool molten plastics, such as in the extrusion and injection molding processes. They help maintain consistent temperatures and improve the quality of the finished product.

Water treatment: Dry coolers are used in water treatment plants to cool water before it enters the treatment process. They are also used to cool water in recirculating systems used in water treatment and wastewater treatment.

Pulp and paper industry: Dry coolers are used in the pulp and paper industry for cooling process fluids, such as water and chemicals used in the papermaking process. They are also used to cool air in paper mills to improve air quality.

Paint and coatings industry: Dry coolers are used in the paint and coatings industry to cool solvent and water-based coatings during manufacturing.
 
Renewable energy: Dry coolers are used in various renewable energy applications, such as cooling geothermal and solar power plants. They are also used in cooling wind turbines to maintain optimal operating temperatures.

Gas compression: Dry coolers are used in gas compression facilities to cool the compressed gas, such as in natural gas compressor stations and air compressor systems.

Chemical plants: Dry coolers are used in chemical plants for various cooling applications, such as cooling reactor vessels and distillation columns.
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
Our Advantages

 

Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
 
Company Profile


VRCOOLERTECH CST Company

We specialize in designingmanufacturing and exporting refrigeration equipments for the varied industries since 2004.
When it comes to building heat exchanger for any application VRCOOLERTECH CST Company has the capability to meet your requirements. If you need a heat exchanger using water, steam, refrigerant, glycol, ammonia, CO2 or any other medium, CST Company can build it for you. We build heat exchanger for replacement of existing heat exchanger or for new jobs, as well. We make standard copper tube / aluminum fin commercial heat exchanger and we build heavy industrial heat exchanger for process applications. You will be hard-pressed to come up with a job we can't handle.

Changzhou Vrcooler Refrigeration Co.,Ltd is the professional design and manufacturer of various specifications of the 
condenser,evaporator, radiator, unit air cooler, heat exchanger production enterprises, with a strong refrigeration and thermal technology professional R &D Team.

Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System

Test Report & Certifications
Leak test report:Before package, we will do the pressure test in the pool to check if the product leak. (Process: Connect the inlet/outlet of the product to the tube s then put nitrogen in it, and put the product in water. If there is no bubbling, there is no leak.)
Pressure Test Report:Under the pressure test, this product has no leakage; no visible abnormal deformation; no abnormal noise; the test conclusion is qualified.

ISO 9001 Certifications
Ge Jenbacher Jms 420 GS-B. L Gas Engine Rediator Gas Turbine Generator Cooling System
FAQ
Q1: What is your strength ?
A: Design and manufacture.

Q2: How long is your delivery time?
A:Different products' production time is different. Generally, it needs 10 to 40 working days.

Q3: What is your terms of payment ?
A:50% TT deposit in advance, 50% TT balance before delivery.

Q4: Any other products except dry air cooler ?
A: Yes.
Our 3 main products are: Condenser and Evapotator, Industrial air cooler and Unit cooler and Coil.

Q5. How to contact with you ?
A: 24hours online from TradeManager, quick answer, or email with us, wechat, skype, whatsapp is available.